Producten
AP80 Display Controller
- Display for position and speed
 - Cam controller
 - Signal converter
 - Speed monitor
 
The uC controlled AP80-XXX has interfaces for several sensors. Position as well as speed can be displayed. Switching points or preset can be set for both. The unit can be supplied with a modul for 32 tri-state data outputs or a modul with 48 in- or outputs. Front buttons or the DST40 programming tool can be used for setting up.
| Discription | Data | 
|---|---|
| Supply voltage | 10 - 35V DC | 
| Frontsize | 144 x 72 mm | 
| Display | 8 digits, 14 mm | 
| Sensorinput | Incremental, SSI, Parallel, Start/Stop | 
| Digital inputs | 6 | 
| Digital outputs | 9 | 
| Analog output | 1 (optional) | 
| Communication | RS232, RS422/485, CANbus | 
| Data in- en uitgangen | 32 Tristate (F modul) / 48 in and 48 out (P modul) | 